4.3.9 Recap
Recap
- Two rules: around every closed path (Ampère's law), and at every node (flux lines do not end).
- Reluctance , mmf , and the loop rule , Eq. (4.3.16). The dictionary of Table 4.3.1 turns every magnetic circuit into a resistor network: series (same flux), parallel (same nodes), mesh equations (4.3.13)–(4.3.14) for several loops.
- The air gap: , so a gap of already equals the whole iron path, and in most gapped circuits the gap sets the flux, .
- Nonlinear iron: forget , read from the – curve at the of each branch, write for the iron and for the gaps, and add around the loop, Eq. (4.3.21). Saturation near is the ceiling, the hysteresis loop area is the loss per cycle, soft materials for cores and hard ones for magnets.
- Devices: the transformer (, ideal when , , magnetising inductance ), the motor (two gaps in series with the yoke and the rotor), the write head (a nanometre-scale gapped ring, ), the reluctance motor (, pulled to minimum reluctance) and the lifting magnet ( per pole face).
- Fringing and leakage: fringing enlarges the gap area, , and lowers . Leakage is a reluctance in parallel, and the coil carries to times the useful flux.